Colorimetry: a brief history of colour measurement.

Starting in the early 1800s, investigations were made into the perception of colour and how it relates to the physical properties of light. Over time a number of metrics to describe the relationship have been formulated.

LL
LightLab Technical Team
Editor’s note. This is one in a historical series of documents published in our Lab Notes series around the turn of the century. The series is a snapshot of understanding at that time. We hope that you find it interesting.

The CIE

The Commission Internationale de l’Eclairage, known as the CIE, was established in 1913 and is the internationally recognised authority on photometry and colorimetry. It was integral in guiding the development of colour-related metrics.

Trichromatic colour measurement

The idea that a colour could be matched by a combination of red, green and blue stimuli has been accepted since 1853, when Grassmann first postulated the theory. A later milestone was the acceptance in 1924 of the standardised spectral response curve of the human eye, usually known as the V-lambda curve.

The colour matching equation is based on the premise that a certain quantity of red light (R), plus a certain quantity of blue light (B), plus a certain quantity of green light (G), can match a given quantity of most colours that can be perceived by the eye (C).

Expressed as proportions, r = R ÷ (R + G + B), g = G ÷ (R + G + B) and b = B ÷ (R + G + B), so that r + g + b = 1. The colour can then be found on a two-dimensional chromaticity chart. Note that chromaticity does not encode any information about brightness.

CIE 1931

By the 1930s colour measurement had moved from observer comparisons to the colorimeter, an instrument-based approach that refined accuracy and reproducibility. In 1931 J. Guild published the results of experiments showing the spectral coordinates for the three primary colours, red, green and blue, matched against a standard white light. At each wavelength the coordinates added to 1.0, but one or more of them was always negative.

In 1930 D. B. Judd had put forward a proposition that if three new imaginary stimuli, to be known as X, Y and Z, were used, the disadvantages of the R, G, B system could be overcome. When the colour triangle was redrawn, most colours fell within the new triangle. The standard white, later known as equal energy white, is matched by equal parts of X, Y and Z.

The primary advantage of the method is that all real physical stimuli lie within the X, Y, Z triangle. The 1931 CIE chromaticity chart is plotted in terms of these reference stimuli, with units based on an equal energy white. To calculate the colour coordinates of a specific light source requires its spectral power distribution and the colour matching functions.

The standard observers

The colour matching functions were determined empirically in the late 1920s through experiments conducted independently by Wright and Guild. Human observers matched pure monochromatic colours using a combination of red, green and blue primaries, establishing the 2° Standard Observer.

Further research by Stiles and Speranskaya in the 1950s indicated that a 10 degree field of view was more appropriate for observers. The colour matching functions for a 10° observer were adopted in 1964.

Related service

Need colour metrics for a light source?

LightLab measures chromaticity, CCT, CRI and spectral distribution as part of its testing services.