HomeCalibrationGloss Meter Calibration
Calibration · Gloss meters

Gloss meter calibration.

A gloss meter measures the specular gloss of a surface, what we perceive as its lustre or shininess. A laboratory calibration compares the meter response against known reference tiles, so that future measurements are traceable and accurate.

Geometries
20° · 60° · 85°
Unit
Gloss Units (GU)
References
Gloss tiles
Accreditation
NATA 2258
What we calibrate

Your meter against our reference tiles.

LightLab maintains a set of reference tiles to support the calibration of gloss meters. Our reports include the response of the meter to a set of gloss, semi gloss and zero gloss reference surfaces, at the geometries the meter supports.

High gloss reference
Reference tile
Semi gloss reference
Reference tile
Zero gloss reference
Reference tile
Measurement geometries
As supported by the meter
Gloss of materials
Specular inclusive or exclusive
In detail

How gloss is measured.

Specular gloss is specified in Gloss Units (GU). It is measured by projecting a beam of light of known intensity at a fixed angle onto a surface and measuring the intensity of the component reflected at the same angle on the other side of the surface normal.

The geometry of the light path is set by the standard in use. ISO 2813, one of the most widely recognised and used by the paint industry, defines three angles: 20°, 60° and 85°. It is similar to national standards such as AS 1580 in Australia, DIN 67530 in Germany and ASTM D523 in the United States.

A gloss meter includes one or more working reference tiles, used for a working calibration before each use. From time to time a laboratory calibration compares the meter against a known reference tile. The offsets reported are then applied to future measurements.

What you receive

Offsets you can apply to every reading.

Calibration report

The response of your meter to each reference surface at each geometry, with the offsets to apply.

Traceable results

The laboratory maintains reference detectors that are traceable to the SI system of units, so your readings can be defended.

A calibration history

Regular laboratory calibration shows whether the meter or its working tile has drifted.

Frequently asked

Common questions, answered.

The working tile supplied with the meter is used for a quick working calibration before use. A laboratory calibration checks the meter against independent reference tiles, which is what gives your measurements traceability.
Ready to begin

Send us your sample,
we’ll send back certainty.

Request a quote for testing or calibration and hear back from a technician, not a sales representative, within one business day.