What LM-79 covers

LM-79 is an approved method of the Illuminating Engineering Society of North America (IESNA) for measuring the electrical and photometric performance of solid-state lighting products. The standard covers total flux (light output), electrical power, efficacy, chromaticity and intensity distribution.

The results of an LM-79 test identify the key performance metrics of a product: photometry, colorimetry and energy efficiency. Photometric results, coupled with electrical measurements, feed into efficacy and energy efficiency calculations.

What LM-79 does not cover

LM-79 is a snapshot of performance. It does not tell you how long the product will last. That question is answered by a combination of three other documents: LM-80, an in-situ temperature measurement and TM-21.

LM-80: the LED module life test

LM-80 prescribes a test method in which a batch of LEDs is mounted onto a carrier and tested at a specific drive current and ambient temperature. At intervals during the test the luminous flux, CCT and other metrics are measured. Three temperatures are used: 55°C, 85°C and a temperature chosen by the LED manufacturer.

The samples are operated for 1,000 hours, removed from the oven, allowed to cool to 25°C and measured. They are then placed back in the oven and the process is repeated for a minimum of 6,000 hours, approximately nine months. Because of its duration and cost, LM-80 is typically performed by the manufacturer of the LED module, who then makes the data available.

ISTM: temperature inside your luminaire

In-situ temperature measurement is an important part of ensuring LED products meet energy efficiency and lifetime expectations. The ISTM test measures the operating temperature and drive current of the LEDs inside the luminaire, as would be encountered when the luminaire is operated normally. The standard prescribing the luminaire conditions during the test is IEC 60598.

TM-21: projecting lifetime

Once the LM-80 test has concluded, the measurements are used to determine a depreciation curve for the luminous flux at each temperature. The data is extrapolated using the method described in Technical Memorandum TM-21 to determine the lumen maintenance life projection. The end point of the extrapolation is typically 70% of the initial light output.

If the temperature and drive current measured in situ in the luminaire are within the bounds of the LM-80 report, TM-21 can be used to estimate the expected lifetime of the luminaire.

Energy efficiency schemes

The state governments of Australia foster schemes to improve energy efficiency. There are differences in implementation, but all rely on creating financial incentives for organisations to invest in energy-saving products, and all rely on evidence-based documentation that has test laboratories at its source.

For LED lighting, the majority of performance testing in Australia is to LM-79 and LM-80. Requirements differ between schemes and change over time, from a single measurement of electrical supply power (light circuit power) through to a full LM-79 test supported by LM-80 and other manufacturer data. Check the current scheme rules, or ask us, before you commission testing.

What you receive from the laboratory

Distribution photometry yields a significant mass of data, best represented in a form that is computer readable. We generate photometric data in many formats, including IES LM-63, the CIE format defined in Publication 102, Eulumdat and Phillum. The charts that appear on our test reports can also be issued electronically for inclusion in your catalogues.

Related service

Need LM-79 results for your product?

LightLab tests LED luminaires to IES LM-79 and performs in-situ temperature measurements at its Brisbane laboratory.