The instrument
A typical range of measurement for a luxmeter is from 1 lux to 100,000 lux. Specialised meters are available for reading levels above and below that range.
For accurate measurements the detector should be cosine and colour corrected. Cosine correction allows for the effects of light falling on the cell at oblique angles. Colour correction is necessary to match the spectral sensitivity of the human eye, defined by the spectral response of the CIE Standard Observer and known as the V-lambda curve. There is a wide range of lightmeters in the marketplace, so before performing measurements consider the accuracy and range of measurement required.
Field measurements
Measurements of illuminance in a lighting system should be made after dark. With outdoor installations this is essential. For interior installations it is often possible to exclude daylight with blinds or curtains. The established “lights on, lights off” technique can be reasonably accurate, provided the daylight is not varying too widely and the survey time is not too long.
An installation of discharge or fluorescent lamps should be switched on at least half an hour before measurements are taken, to allow the lamps to warm up completely. Fully enclosed luminaires may need longer. New discharge or fluorescent lamps should have a burning-in time of at least 100 hours before measurements are taken.
The procedure will depend on whether the space is furnished or unfurnished, occupied or unoccupied. In some instances the effects of body shadow should be taken into account. Where the measuring plane is not specified, a height of one metre above ground or floor level is generally considered acceptable. A monopole with a small platform to support the meter helps to achieve a consistent height.
Field measurements are only valid for the conditions that exist at the time of the survey. If they are part of an ongoing survey, record the following:
- details of the luminaires, including installation age
- meter make and serial number
- a detailed description of the surveyed area, with a diagram of the measurement points and photographs
- the height of the measuring plane
- time of day
- ambient temperature
- condition of interior surfaces, clean or dirty
Measuring the average illuminance
A lightmeter indicates the illuminance at the point of measurement only, not the average in the space. To find the average, divide the area into a number of equal areas that are as nearly square as possible. Measure the illuminance at the centre of each and average the results.
The minimum number of areas required for accuracy can be determined by first calculating the room index: k = (length × width) ÷ (Hm × (length + width)), where Hm is the height of the luminaires above the plane of measurement.
| Room index (k) | Minimum points for ±5% | Minimum points for ±10% |
|---|---|---|
| Below 1 | 8 | 4 |
| 1 to below 2 | 18 | 9 |
| 2 to below 3 | 32 | 16 |
| 3 and above | 50 | 25 |
The working plane is usually taken to be 0.85 m for work benches or 0.72 m for desk-top height, unless the main plane of work is known to be at some other height. If the proposed points coincide with luminaire positions, or sit in a constant relationship to them, increase the number of measurement points.
Luxmeter maintenance
As a general rule meters should be recalibrated every year. If a meter is to be used in a legal case it should have been recalibrated within the preceding 12 months. It is good practice to have the calibration checked either just before or just after the survey if the results are likely to be subject to litigation.
Although the present-day luxmeter is a fairly robust device, all meters need to be handled carefully. They should never be left in the glove box of a car for long periods in the summer months. Not only will this upset the calibration, the cell can be destroyed by the heat.
Luxmeter accuracy
Manufacturers usually quote illuminance accuracy as a percentage of the reading, typically in the range 2% to 5%. This is exclusive of errors introduced by the cosine response and spectral response of the meter.
A calibration history shows how stable the meter is over time. Following a calibration, check the previous report to see whether there has been a shift in accuracy. If significant, it could have a bearing on readings taken since the last calibration, and may indicate that the meter has suffered damage. Calibration reports should be filed for future reference.
Types of illuminance
Illuminance is typically measured with the face of the detector horizontal, and horizontal illuminance is the common measurement in lighting standards. Vertical illuminance has its place too: the illuminance on a wall chart, for example, is measured with the detector vertical.
Semi-cylindrical illuminance, which needs a special detector, can be useful in modelling the human figure and has been found more reliable than horizontal illuminance in outdoor areas such as car parks and public places. Cubic illuminance describes the light arriving at a point in terms of three pairs of mutually perpendicular planes, and indicates the spatial distribution of light, shade and modelling. It is particularly relevant where recognising a facial expression matters, such as conference and video conferencing rooms.
Is your lux meter due for calibration?
LightLab operates a NATA-accredited calibration laboratory for illuminance and luminance meters.